公司地址:广州市增城区石滩敏捷绿湖首府馨湖三街14号
服务热线: 02029808639
技术支持:13711185428
目录
1 安全 3
2 准备工作...................................................................................................4
3 Mic-SE32A-0110控制板...........................................................................5
3-1 Mic-SE32A-0110控制板概貌..............................................................5
3-2 Mic-SE32A-0110控制板端口说明.......................................................5
4 SM-02-C轿厢板和SM-03-B指令板..........................................................9
4-1 SM-02-C轿厢板和SM-03-B指令板概貌.............................................9
4-2 SM-02-C轿厢板端口说明...................................................................9
4-3 SM-03-B指令板端口说明.................................................................11
4-4 SCOP-SCON-0410轿内显示板概貌………………………………………...11
4-5 SCOP-SCON-0410轿内显示板端口说明……… …………………………12
5 SLOP-SCON-0410 厅外显示板............................................................13
5-1 SLOP-SCON-0410 厅外显示板概貌.................................................13
5-2 SLOP-SCON-0410 厅外显示板端口说明..........................................13
6 SMLCD...................................................................................................15
6-1 概述..................................................................................................15
6-2 操作说明...........................................................................................15
7 变频器自学习…………………………………………………………..……… 16
3-1短接线..............................................................................................17
3-2通电..................................................................................................17
3-3设置曳引机参数................................................................................17
3-4确认电机运转方向.............................................................................17
3-5自学习..............................................................................................18
3-6自学习故障以及对策.........................................................................18
8 安装运行.................................................................................................20
8-1机房..................................................................................................20
8-2通电..................................................................................................21
9 快车调试.................................................................................................22
9-1准备工作...........................................................................................22
9-2通电..................................................................................................22
10 电梯舒适感调整......................................................................................25
10-1 电梯载荷控制仪..............................................................................25
10-2 起动力矩补偿..................................................................................27
10-3舒适感整体调整………………………………………………………………….. 29
11 电梯参数表和故障代码表........................................................................29
11-1电梯参数表.....................................................................................29
11-2 电梯参数详细说明...........................................................................33
11-3 电梯故障代码表..............................................................................43
12 变频器参数.............................................................................................46
13 变频器部分代码简述及对策…………………………………………………..49
1 安全
安全要求 安装现场应按安全操作规程要求配置相应的安全防护设备。所有安装人员应按要求
正确使用安全防护设备及设施。
图1. 安全设备
1 安全帽
2 防护眼镜
3 安全带
4 防护鞋
5 防护手套
· 在工地和井道安装合适的照明设备。
· 应立即更换或补充被损坏或丢失的安全装备。
· 如果有坠落的风险,应扣好安全带和安全帽。
· 正确使用并妥善保管工具。
· 遵守安装工具及设备制造厂的使用说明。
· 所有安装人员应对自己的安全及健康负责。
2 准备工作
工具与设备 万用表
手持式操作器
WAGO 工具
AMP 工具
一般电工工具
警告
When handling PCBs, always keep to the rules concerning "Handling
MOS/CMOS"
文件 装箱清单
电气原理图
土建布置图
3 Mic-SE32A-0110控制板
序号 步骤 备注
3-1 Mic-SE32A-0110控制板概貌
300
3-2 Mic-SE32A-0110控制板端口说明
JP1,JP2,JP3为外部开关信号输入口
l JP1.1 输入X0,检修信号,断开为检修,闭合为自动
l JP1.2 输入X1,上行信号. 在检修时闭合为点动上行,在司机时闭合
为上行换向
l JP1.3 输入X2,下行信号. 在检修时闭合为点动下行,在司机时闭合
为下行换向
l JP1.4 输入X3上行第二终端换速开关, 超过1 米/秒以上电梯要求
使用,
l JP1.5 输入X4, 下行第二终端换速开关, 超过1 米/秒以上电梯要求
使用
l JP1.6 输入X5,上行限位开关
l JP1.7 输入X6,下行限位开关
l JP1.8 输入X7,上行单层终端换速开关.
301
l JP1.9 输入X8,下行单层终端换速开关
序号 步骤 备注
l JP1.10 输入X9,上平层开关
l JP2.1 输入X10,下平层开关
l JP2.2 输入X11,调速器故障输出信号
l JP2.3 输入X12, 火灾返回开关
l JP2.4 输入X13, 第二抱闸开关检测
l JP2.5 输入X14, 备用
l JP2.6 输入X15,调速器进线接触器检测
l JP2.7 输入X16,调速器出线接触器检测
l JP2.8 输入X17,抱闸继电器检测
l JP2.9 输入X18,前门门区开关信号输入,当选择独立门区开关时
用(当有前后门时,建议采用独立门区开关)
l JP2.10 输入X19,调速器运行信号检测,检测到此信号闭合则抱闸可
以张开
l JP3.1 输入X20, 再平层或提前开门继电器检测
l JP3.2 输入X21, 消防开关
l JP3.3 输入X22,抱闸开关检测
l JP3.4 输入X23, 曳引马达热保护检测输入
l JP3.5 输入X24,上行第三终端换速开关, 当采用数字量多段速给
定,且电梯速度超过2 米/秒以上电梯要求使用
l JP3.6 输入X25,下行第三终端换速开关, 当采用数字量多段速给
定,且电梯速度超过2 米/秒以上电梯要求使用
l JP3.7 X0-X25 输入信号公共端
l JP3.8 X0-X25 输入信号公共端
l JP3.9 X0-X25 隔离电路电源负极,0V
l JP3.10 X0-X25 隔离电路电源正极,+24V
JP12.1-JP12.6 是主机板工作电源
l JP12.1 主控制器工作的0V电源
l JP12.2 主控制器工作的0V电源
l JP12.3 +5V 电源
l JP12.4 主控制器工作的+24V电源
l JP12.5 主控制器工作的0V电源
302
l JP12.6 主控制器工作的0V电源
JP4.1-JP4.4(CAN1) 接外呼板和轿厢板
l JP4.1 外呼和轿厢串行通讯信号端,TXA1-
l JP4.2 外呼和轿厢串行通讯信号端,TXA1+
l JP4.3 备用0V输出
303